home *** CD-ROM | disk | FTP | other *** search
- Path: kanto.cc.jyu.fi!not-for-mail
- From: trossi@kanto.cc.jyu.fi (Timo Rossi)
- Newsgroups: comp.sys.amiga.hardware
- Subject: Re: 1084 Monitor
- Date: 31 Jan 1996 20:09:24 +0200
- Organization: University of Jyvaskyla, Finland
- Message-ID: <4eob8k$e7i@kanto.cc.jyu.fi>
- References: <4ehncb$c52@nw002.infi.net>
- NNTP-Posting-Host: kanto.cc.jyu.fi
- X-Newsreader: TIN [UNIX 1.3 950824BETA PL0]
-
- Robert Arthur (rarthur@infi.net) wrote:
- > I have a 1084d monitor which has started doing a odd thing,, the picture
- > shrinks & pops back every so often.. I mean,, not too much,, maybe a 1/8 to
- > a 1/4 of a inch movement,, but it drives me nuts.. Any idea how to fix it?
- >
- > Sometimes I hear a crackling before each " picture twich ",,
-
- This seems to be common with these monitors. Normally caused
- by bad solder joints between the flyback transformer and the circuit
- board.
-
- But be careful if you try to fix it yourself. Dangerous high
- voltages may be present, even after the monitor has been
- disconnected from mains.
-
- --
- << Timo Rossi -- email: trossi@jyu.fi >>
-